Oil & Gas applications for FPZ’s products.
FPZ side channel blowers, metering pumps and industrial fans are used in the following fields of application:
- Oil mist separation – downstream of Oil & Gas plants
- Remediation of contaminated sites – downstream of Oil & Gas plants
- Refinery waste water treatment
- Refinery water treatment
- Water treatment in cooling towers
- Boiler water treatment in refineries and petrochemical plants
- Gas odorization systems
- Combustion of fuel
- Flare system
Oil mist separation – downstream of Oil & Gas plants
In power plants and refineries, the oil mists of gas / steam turbines, gearboxes, diesel engines and compressors are sucked in to allow the oil to return to the plant.
Oil Vapour Extraction
The side channel blowers are used in suction to convey the oil mist through the separation chambers of a filter, which collect the oil particles which are then discharged or reintroduced into the system, returning clean air to the environment.
Our solutions
The blowers installed for this application are from the MS range.
Available with directly driven motor or elastic motor coupling in horizontal or vertical form (MOR, GOR and GVR)
ATEX version
MS
Single impeller single stage
Remediation of contaminated sites – downstream of Oil & Gas plants
It is often necessary to improve the soil condition on Oil & Gas plants by: eliminating and / or reducing the pollutants released into the subsoil during processing.
Remediation of soil
The side channel blower is used in compression to induce the air to pass through the ground through an extraction well while a second blower sucks in the volatile pollutants bringing them to the surface through a second well leading them to the blast chillers.
Our solutions
Three families of blowers are used in the remediation of contaminated sites.
Available with directly driven motor or elastic motor coupling in horizontal or vertical form
(MOR, GOR and GVR)
*ATEX version
MS
Single impeller single stage
MD
Single impeller double stage
TD
Double impeller double stage*
Wastewater treatment
FPZ side channel blowers are used in the water purification process, in traditional activated sludge plants or in systems with membrane bioreactors i.e. MBR (Membrane Biological Reactor) and SAFF Submerged Aerobic Fixed Film reactor).
1. Oil separation
The oil separation, or degreasing process, aims to remove the excess of oils and fats from the water. The air is blown from the bottom of the tanks through porous diffusers. The emulsified fats, pushed towards the surface, are discharged into a collection well.
2. Biological oxidation
In the biological oxidation phase, the air blown through porous diffusers provides the oxygen that degrades the organic substances present in the wastewater.
3. Air-lift
The air generated by the blower feeds the air-lift pump, used for lifting and recirculating water with mud or sand.
Our solutions
Three families of blowers are used in wastewater treatment:
Available with directly driven motor elastic motor coupling in horizontal or vertical form (MOR, GOR and GVR)
MS
Single impeller single stage
MD
Single impeller double stage
TD
Double impeller double stage
Refinery water treatment
Doseuro pumps are used in refineries located in Oil & Gas plants upstream of the oil extraction processes.
Injection of chemicals
Dosing pumps are used to inject chemicals into the water, used in fracking processes, capable of eliminating limescale deposits and encrustations on the pipes; avoiding inefficiencies and unplanned stops due to breakdowns or breakages.
Our solutions
The metering pumps used in refinery water treatment are from the PDP series.
PDP series – SDI type
Sandwich Hydraulic
Diaphragm
PDP series – A-I type
Positive Return Plunger
Water treatment in cooling towers
To increase the productivity of industrial plants, the water present in the cooling towers is treated thanks to the use of dosing pumps.
Reduction of corrosion and limescale deposits
The dosing pump is used to inject chemicals, such as corrosion inhibitors (e.g. bicarbonates) to neutralize acidity, limescale inhibitors (e.g. phosphoric acid) to prevent contaminants from forming limescale deposits.
Our solutions
The metering pumps used in water treatment in cooling towers are from the PDP series and compliant with the API 675 standard.
PDP series – SDI type
Sandwich Hydraulic
Diaphragm
PDP series – A-I type
Positive Return Plunger
Boiler water treatment in refineries and petrochemical plants
The metering pump is used for the dosage of chemicals necessary for the treatment of the water in the boiler, useful for the prevention of damage and for the protection of the boiler.
1. Corrosion reduction
The pump doses chemicals (hydrazine and ammonia) to eliminate erosion, corrosion and the accumulation of limescale inside the boiler.
2. Reduction of fouling phenomena
In addition, the metering pump is also used to inject trisodium phosphates, for pH correction.
3. Disinfection
The pump doses chemicals such as sodium hypochlorite or benzene.
Our solutions
The metering pumps used in the water treatment of the boiler are from the PDP series and compliant with the API 675 standard.
PDP series – SDI type
Sandwich Hydraulic
Diaphragm
PDP series – A-I type
Positive Return Plunger
Gas odorization systems
The pumps are used to dose odorants into natural gas.
Dosing of odorant in natural gas
The pumps are used to dose the odorant in the natural gas. The pump is controlled by software which, based on the request of the control unit, sends to PLC the information necessary to increase or decrease the quantity of odorant to be injected.
The presence of odorant in natural gas, which by nature is odorless, allows it to reach the necessary safety standards.
Our solutions
The pumps used for odorant dosing in natural gas are hydraulic diaphragm with high pressure spring return.
SR Series – Type B & BR
Hydraulic diaphragm
SR Series – Type SD
Spring returnmechanical
diaphragm pumps
Combustion of fuel
The fan is used in petrochemical plants and refineries to convey the air into the combustion furnaces.
Constant air supply
The fan is used to suck in the right amount of air at the environmental conditions, bringing it to the ideal pressure and temperature to allow the ovens a regular and uniform combustion of the fuel.
Removal of fumes
The fan is used to produce a negative pressure capable of removing the fumes from the combustion furnace and conveying them to the chimney.
Our solutions
Arivent fans suitable for air treatment for fuel combustion work at high pressure, high temperatures and in explosive risk areas. They have ATEX certification and comply with the API 673 standard.
ATEX version
S – GPH – PF – FD – ID series
Flare system
Fans are used in refineries to allow excess natural gas, extracted together with oil, to burn.
Mixing of gas and air
The fan is used to mix air and natural gas avoiding the escape of pure gas from the chimney.
Our solutions
Arivent fans ideal for flare systems comply with API 560 and 673 standards.
ATEX version
FD series
[fpz-gamification-pin-manager]
Download area
Download our FPZ, Doseuro and Arivent catalogues.